Subscribe to Zeeco Updates

CATEGORIES:

Filter:

BACK TO PRESENTATIONS

Nitrogen & Syngas 2019 – Berlin, Germany – March 5-6, 2019

 

Application Overview:

  • Downfired primary reformer furnace
  • European ammonia production facility
  • 105 downfired burners > 40 years old
  • NOx emissions in range of 250-300 mg/Nm3

NitrogenSyngas1NitrogenSyngas4


 

NitrogenSyngas-furnace-test

Burner Performance

  • Burners are achieving 90 mg/Nm3 NOx
  • 3.0% O2 measured in the flue gas; therefore, further reductions will improve NOx
  • No flame-to-flame interaction
  • Improved heat flux profile

 


 

Nitrogen Syngas burner

Conclusion

  • Zeeco supplied 105 GB Single Jet inserts for a downfired reformer at a European ammonia facility
  • NOx emissions, heat flux profile, and flame-to-flame interaction were confirmed by CFD and burner testing
  • Current NOx emissions average 90 mg/Nm3 at 3% 02 which meets European legislation and NOx guarantees
  • Burners are operating with lower excess air; therefore, fuel gas consumption rate is lowered in the radiant section
  • NOx emissions can be reduced further if the furnace excess air is trimmed

Download Presentation

BACK TO PRESENTATIONS